Hi I am looking for a contractor to complete a whole house re-wire.. I have pulled together... in Kingsley

Needed: Electrician in Kingsley, NN3

Job submitted:Dec 2, 2011

Job description:Hi I am looking for a contractor to complete a whole house re-wire.. I have pulled together what I believe are the requirements: Electrical Requirements: Basement: Replace old consumer unit with 17th edition consumer unit Provide earth bonding for both water and gas services 1 * Fix light pendent 1 * 1 gang 1 way light switch Utility: 1 * Fix light pendent 1 * 1 gang 1 way light switch (on new utility stud wall) 2 * double sockets Stairwell & Area outside utility: 1 * Fix light pendent at the head of the stairs 1 * Fix light pendent outside utility 1 * 1 Gang 2 way light switch (on new utility stud wall) 1 * 2 way light switch in the kitchen 1 * double socket Large Basement Room: 2 * lighting points in the ceiling 1 * 1 Gang 1 way light switch 4 * Double sockets 1 * Fuse connection for Boiler unit 1 * RJ45 Network and TV Outlet Lounge: 1 * lighting point in the ceiling 3 * 5A lighting outlet at low level 1 * 2 gang 2 way light switch to control 5A lighting outlets and lounge ceiling light 3 * double sockets behind the TV 3 * double sockets around the room 1 * RJ45 (network) and TV light Dining Room: 1 * lighting point in the ceiling 1 * 2 gang 2 way light switch to control the lounge and dining room ceiling lights 4 * Double sockets 1 * RJ45 (Network) and TV outlet 1 * 2 gang 2 way light switch near to French doors to control the dining room and outside wall lights. Hall: 1 * 3 Gang 2 way light switch to control the outside /hall/landing lights 1 * intermediate light switch for hall light 1 * 1 gang 2 way light switch for LED marker lights 1 * lighting point in the ceiling 2 * double sockets 1 * smoke detector Kitchen (Extension): 1 * Grid plate to switch; 1 cooker point/1 water heater/ 1 hob extractor 1 * smoke detector 1 * CO detector 1 * 4 gang 2 way light switch to control both kitchen spot light circuits/bar lights/basement stairwell 8 * Low energy spot lights (2 rows of 4 outer) 4 * low energy spot lights (1 row of 4 inner) 3 * lighting points above the bar (not supplied) 8 * double sockets 1 * RJ45 (Network) and TV outlet at the garden end of kitchen 1 * fuse connection unit for electric fireall/landing/ 1 * 4 gang 2 way light switch to control one kitchen spot light circuit/barlights/rear outside wall lights/garden lights Porch: 1* lighting point in the ceiling 1 * ceiling mounted PIR Stairwell: 7 * LED low level marker lights up the stairs to first floor 1st Floor Landing: 1* smoke detector 1 * 3 Gang 2 way light switch to control the hall/landing/LED marker lights 1 * 2 Gang 2 way light switch to control the first floor landing / second floor landing 1 * Lighting point in the ceiling 1 * single socket 1 * 1 Gang 1 way light switch for the bathroom 1 * 1 Gang fan isolation switch for the bathroom Bathroom: 4 * IP rated polished chrome 12v spotlights 1 * fuse connection unit for power shower 1 * extractor fan 1 * feed to water heater (immersion heater) Master Bedroom: 1 * lighting point in the ceiling 1 * 5A lighting outlet at low level each side of the bed 1 * 3 gang 2 way light switch on each side of the bed and near the main door to control 5A lighting outlets and ceiling light 1 * double socket on chimney breast 1 * double socket on either side of the bed 1 * RJ45 (Network) and TV outlet 1 * 1 gang 1 way light switch for ensuite 1 * 1 gang fan isolation switch for ensuite En Suite: 2 * IP rated polished chrome 12v spot lights 1 * Fuse connection unit for power shower 1 * 12v extractor fan with light 1 * Shaver point Bedroom 2 (First floor front): 1 * Lighting point in the ceiling 1 * 1 Gang 1 way light switch 3 * double sockets Study: Distribution point for all network outlets 1 * Lighting point in the ceiling 1 * 1 Gang 1 way light switch 2 * Double sockets below desk 1 * double socket above desk 2 * double sockets on other walls 2nd Floor Landing: 1 * Smoke detector 1 * 2 gang 2 way light switch to control 1st floor / 2nd floor landing 1 * Lighting point in the ceiling behind glass feature 1 * single socket Eaves Storage: 1 * fix light pendent 1 * 1 Gang 1 way light switch Loft: 1 * fix light pendent 1 * 1 gang 1 way light switch 1 * single socket for tv Bedroom 3 (rear 2nd floor): 1 * lighting point in the ceiling 1 * 1 gang 1 way light switch 3 * double sockets Bedroom 4 (front 2nd floor): 1 * lighting point in the ceiling 1 * 1 gang 1 way light switch 3 * double sockets Outside Rear: 1 * IP rated double socket 2 * Brushed chrome wall lights along the kitchen wall 4 * Low energy black bulkhead lights along garden wall Run SWA cable to garage Garage: 1 * Consumer unit to control power in the garage and garden lights 2 * IP rated single fluorescent light fittings 1 * 1 Gang 1 way light switch 3 * double sockets 1 * outside wall light 1 * 2 gang 2 way IP rated outside light switch to control the garden and outside garage light 1 * power point for electric gates Outside front: 2 * brushed chrome wall lights either side of the front door

Budget:Under £8,000

Need a recommended electrician?

  • Rated People is here to help
  • The electricians who use our site cover a wide range of projects including electrical circuits wiring and lighting
  • Post your job, give a clear description and up to 3 recommended electricians will contact you to quote on the work

Get the recommended electrician you need with Rated People.

Job location, Kingsley