The tank isn't heating up. Had a new element put in about 5 years ago. It's a hard water area so we have tended to need a new one about this frequency. Not sure if this is the problem, this time, or not.
A man called Lazmir phoned to make an appointment for the following morning to fix our water heater. He did a very good job, charged a reasonable price and was a nice chap who cleaned-up after himself. I would be very happy to put any more work his way and to recommend him.Chris
Good satndard of work, did what he said he was going to do and gave the right solutions allround. Really pleased with his communication, attention to detail and final result.Bruce
Our Megaflow system seems to have a problem - the airing cupboard pipes are hissing constantly and the overflow pipe outside is leaking. Shower pressure still fine at the moment though. Please can someone come and look at it for us?
Very polite, businesslike and helpful. Would definitely recommend.Holly
toilet was overflowing to outside pipe. Ajustment screw has now broken so mechanism in system prpbably needs replacing.
Rang within 30 sec of me hitting go on Rated People. Made arrangement to come, did a good job, charged what we agreed. will use R.P. and UA gas again.Jennifer
Need to remove old gas cooker. Cap off gas supply and install new electric cooker. New cooker already at location.
What a breath of fresh air. MJ is very professional, polite and helpful. He was very quick to reply to my call, gave a reasonable quote and completed job the same day, taking great care that I was happy with the outcome. Thank you very much.Dasha
Requiring 2 raised sleeper beds to be removed. Beds are 3 metre square and are 2 sleepers high. (12 sleepers in total) plus topsoil and any unearned plants. All to be removed and disposed off. One area to then be made good and turfed.
James did a thorough job, was honest, hard working and did the work effectively. I would definitely recommend him. Thanks James, we've now finish our project and the garden looks great.Helen
4 parts to the job
1 - The bath and basin taps are trickling continuously. I would recommend
replacing the bath taps as these have been reconditioned before. To
supply and fit a pair of basin taps.
2 - The hot basin tap is heavily corroded due to constantly running an the
supply pipe to the tap has signs of leaking previously. I would
recommend replacing the short length of pipe underneath the basin and
to also fit a new ceramic valve to the tap.
3 - A new water softner bottle needs fitting unscrewing the existing and replacing with a new one
4 - There is some staining on the dining room ceiling from an old leak from
the bathroom. To repair crack, seal with stain block and finish with white
matt emulsion.
Tilehurst, RG31
Under £500
Fit a mains shower (triton) with all new pipework
Lower Earley, RG6
Under £500
Hi, I would like to install power shower in my en-suit and fix 3 radiators that aren't heating up.
Grazeley, RG7
Under £100
unable to flush toilet and overflow running. built in unit access through top panel. TD D212 - A cystern number
Tilehurst, RG31
Under £250
Toilet cistern very noisy and knocking. Probably needs new flushing mechanism.
Battle, RG30
Under £250
repair of combi boiler
pressure droped, opened blue valve to increase pressure
water started poring out of reduce pressure zone valve,
we shut water off, isolated the system
help
Battle, RG30
Under £1,000
Updated : Now bubbling all day. Water is rising in the bowl, in the morning seems fine Original : 1st floor flat in converted house. Toilet has been bubbling for long periods of time. Been plunged, been snaked. Cannot find the manhole for it outside as has been gravelled. Need someone who knows what they are doing as will not pay for another plunger that doesn't work
Woodley, RG5
Under £250
plumbing a new washing machine integrated
Caversham, RG4
Under £1,000
We would like to have three new radiators resited in 3 separate rooms. All rooms have wooden floor boards. Radiator sizes to be fitted are as follows: 450mm x 1600mm Stelrad K2 450mm x 1600mm Stelrad K2 450mm x 1200mm Stelrad K2 Al radiators to be fitted with one Honeywell Vt117e thermostatic radiator valve and one Crestalux balancing valve, using copper piping and fittings and central heating inhibitor/protector liquid. We would like a quote to include supply of the radiators, valves, piping, fittings, inhibitor liquid and labour. Very happy to show around if required.