Ask an expert

Get free help from our community of tradespeople

New ovens

Posted by Ian Dawson, on
I'm installing two ovens which are rated at 3.5Kw can these be run off a single 6mm 32amp supply
MARK HARDACRE

MARK HARDACRE

Yes if its all-ready the cable installed absolutely, They need to be tested to see if disconnection meet the times required and of course be on an RCD. However, if your newly getting this installed my preferred method would be to run in a 10MM2 T&E cable into a Cooker control Unit, then into a double oven connection unit with 2x 6mm Tails, one into each appliance. Hope that makes sense?